Air Handling Unit (AHU) Description

An Air Handling Unit (AHU) is a centralized air treatment system designed to condition (filter, heat, cool, humidify, dehumidify) and distribute clean air to controlled environments such as pharmaceutical cleanrooms, laboratories, hospitals, and production areas.

AHUs are the heart of HVAC systems in sterile facilities ensuring precise temperature, humidity, air cleanliness, and pressure control as per GMP and ISO 14644 standards.


Working Principle

  1. Fresh Air Intake: Ambient air enters through pre-filters.

  2. Air Mixing: Fresh and return air are blended as per design ratio.

  3. Filtration: Air passes through fine filters and HEPA filters for cleanliness.

  4. Cooling/Heating: Air is conditioned via cooling or heating coils.

  5. Humidification/Dehumidification: Air moisture levels are controlled.

  6. Blower Section: A centrifugal fan supplies conditioned air to ducts.

  7. Final Delivery: Treated air is distributed to rooms through diffusers or terminal HEPA units.


Technical Specifications

Parameter Specification
Type Single / Double Skin Modular AHU
Application Cleanrooms, Pharma, Food, HVAC systems
Construction Modular bolted type with aluminum extruded profile
Panel Thickness 25 mm / 43 mm / 50 mm (PUF or Rockwool insulation)
Outer Skin Pre-coated GI / SS 304
Inner Skin GI / SS 304 (optional mirror finish for pharma)
Frame Structure Anodized Aluminum Extrusion with Nylon Corners
Access Doors Insulated hinged doors with view glass and handles
Drain Pan SS 304, sloped design for condensate removal
Fan Type DIDW (Double Inlet Double Width) Centrifugal / EC Plug Fan
Motor Type TEFC, 3-phase induction motor with VFD compatibility
Filter Stages Pre-filter (10 ), Fine filter (5 ), HEPA (0.3 )
Cooling Coil Copper tubes with aluminum fins (DX/Chilled water)
Heating Coil (Optional) Steam / Hot water type
Humidifier (Optional) Steam injection / Spray / Ultrasonic
Air Flow Capacity 1000 CFM to 40,000+ CFM
Static Pressure 50 2000 Pa
Noise Level < 75 dB(A)
Power Supply 415 V AC 10%, 50 Hz, 3 Phase
Control Panel PLC / DDC based control with VFD and sensors

Sectional Components

Section Function
Mixing Box Combines return and fresh air
Filter Section Removes dust and particulates
Cooling / Heating Coil Section Conditions temperature
Blower Section Circulates treated air
Humidification Section Controls humidity
HEPA Section (Final) Provides sterile air for cleanroom

Typical Capacity Range

Model Air Flow (CFM) Motor (HP) Cooling Coil Rows Filter Stages
AHU-1000 1000 1.0 4 2
AHU-3000 3000 2.0 6 3
AHU-5000 5000 3.0 6 3
AHU-10K 10,000 5.0 8 3
AHU-20K 20,000 10.0 8 3
AHU-40K 40,000 15.0 8 3

(Custom sizes and CFM ratings available on request)


Material Options

Component Material Options
Panels PUF Insulated GI / SS304 / Aluminum
Frame Anodized Aluminum Profile
Base Frame GI / SS 304 Heavy Channel
Drain Pan SS 304 with epoxy insulation
Filter Frames Aluminum / GI / SS
Fasteners Stainless Steel with nylon gaskets

Control & Automation Features

  • PLC/Smart Controller with HMI display

  • Differential Pressure Sensors (Filter Monitoring)

  • Temperature & Humidity Sensors

  • Airflow and Damper Control (Motorized Dampers)

  • BMS / SCADA Integration (optional)

  • Variable Frequency Drive (VFD) for energy saving


Applications

  • Pharmaceutical manufacturing & cleanrooms

  • Biotech and healthcare facilities

  • Food and beverage plants

  • Electronic assembly areas

  • Laboratories and research centers

  • Hospital isolation rooms

  • HVAC systems for controlled environments


Compliance & Standards

  • ISO 14644 Cleanroom Air Cleanliness

  • ASHRAE 170 / 62.1 Ventilation Standards

  • GMP / WHO / EU Guidelines

  • EN 1886 / EN 779 / EN 1822 AHU and Filter Standards



Optimal Performance for Industrial Environments

Built for rigorous industrial usage, our air handling units deliver consistent airflow and air quality thanks to their efficient design and strong MS construction. The standard sizes make them versatile for different installation spaces within factories, plants, or warehouses.


Quality Assurance with One-Year Warranty

Every unit goes through strict quality checks, ensuring it meets industry standards. The included one-year warranty gives customers peace of mind about their investment, covering any manufacturing defects or operational issues within the first year.


Flexible Installation and Maintenance

With its rectangular shape and standard sizing, our AHU is straightforward to install and integrate into existing ventilation systems. Maintenance is simplified due to the accessible design, further contributing to long-term operational efficiency.

FAQs of Air Handling unit:


Q: How is the Air Handling Unit installed in an industrial setting?

A: The Air Handling Units rectangular shape and standard sizes make installation convenient for various industrial layouts. Its integration requires basic HVAC connections and electrical supply within the 110-215 Volt range, usually handled by certified technicians.

Q: What warranty coverage is provided with this Air Handling Unit?

A: We offer a one-year warranty from the date of purchase. This covers any defects in manufacturing, materials, or performance, ensuring reliable operation and support for your investment throughout the warranty period.

Q: When should routine maintenance be performed on the unit?

A: Routine maintenance, such as filter changes and system checks, is recommended every three to six months depending on the usage intensity and environmental conditions. Proper maintenance ensures the unit operates efficiently and extends its lifespan.

Q: Where is the Air Handling Unit manufactured and supplied?

A: The units are manufactured in India, utilizing quality materials and industrial standards. As a supplier and trader, we deliver AHUs nationwide, ensuring prompt and reliable supply to industrial customers across India.

Q: What process does the AHU use for air filtration and circulation?

A: The unit employs robust filters and fans housed within the mild steel casing to efficiently capture airborne particles and circulate air. This process helps maintain optimal indoor air quality in demanding industrial environments.

Q: How does using this Air Handling Unit benefit industrial facilities?

A: Industrial facilities benefit from improved air quality and regulated airflow, which are essential for worker health and equipment longevity. The AHUs reliability and efficiency help reduce downtime and support a safer workplace.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Air Handling Unit Category

Air Handling Unit

Air Handling Unit

Minimum Order Quantity : 1 Unit

Material : Stainless Steel

Equipment Materials : Metal

Voltage : 220 Volt (v)

Usage : Industrial

Warranty : 12 Years

SS Static Pass Box

SS Static Pass Box

Minimum Order Quantity : 1 Unit

Material : Stainless Steel

Equipment Materials : Metal

Voltage : 220 Volt (v)

Usage : Industrial

Warranty : 12 Years

SS Laminar Air Flow

SS Laminar Air Flow

Minimum Order Quantity : 1 Unit

Material : Stainless Steel

Equipment Materials : Metal

Voltage : 220 Volt (v)

Usage : Industrial

Warranty : 12 Years